Complete, factory-integrated storage systems around Lumera PCS and our in-house battery management system — one warranty, one commissioning workflow, from a single cabinet to a 7.2 MW turnkey station.
An outdoor, liquid-cooled LFP cabinet built around the LMR-P135. The 832 V nominal string keeps the PCS at full power across the whole state-of-charge window. Cabinets parallel for multi-hundred-kWh sites.
| Energy | 261.25 kWh, LFP (314 Ah cells) |
|---|---|
| PCS | LMR-P135, 135 kW / 148.5 kVA, grid-forming |
| Battery cooling | Liquid cooling |
| BMS | Lumera in-house BMS, cell-level monitoring |
| Output | 480 V, 3P3W / 3P4W — 100% unbalanced load |
| Certification path | UL 9540 / UL 9540A system program — status on request |
The double-energy all-in-one cabinet on the same 832 V platform as the 261: liquid-cooled LFP, in-house BMS with active balancing, and full fire protection. Up to 250 kW AC for larger commercial sites; cabinets parallel to MWh scale.
| Energy | 522.5 kWh, LFP (314 Ah cells) |
|---|---|
| AC power | Up to 250 kW (0.5C / 0.25C configurations) |
| Battery cooling | Liquid cooling |
| BMS | Lumera in-house BMS, bidirectional active balancing |
| Output | 480 V, 60 Hz |
| Certification path | UL 9540 / UL 1973 / UL 9540A program — status on request |
Pre-engineered AC blocks of three or six LMR-P450 units with an integrated medium-voltage transformer. String architecture keeps availability high — one unit down never takes the block down — and grid-forming firmware is standard across the fleet.
| Block ratings | 1.35 MW (3 × P450) · 2.7 MW (6 × P450) |
|---|---|
| PCS | LMR-P450, 450 kW, liquid-cooled, Type 4X |
| DC window | 700–1500 V — 314 / 587 / 648 Ah cell systems |
| MV interface | Integrated step-up transformer, project-specific MV voltage |
| Grid services | Grid-forming, FFR, voltage support, black start |
| Certification path | UL 1741 / IEEE 1547 (PCS), UL 9540 (system) — status on request |
The LMR-S Series is a complete front-of-meter power station built around the LMR-P450: twelve or sixteen string PCS units with an integrated medium-voltage transformer and MV switchgear, assembled and tested at the factory as one unit. The string architecture manages each battery cluster independently — clusters can be added later, and a single module swaps out without taking the station down.
| Station ratings | LMR-S5400: 5.4 MW (12 × P450) · LMR-S7200: 7.2 MW (16 × P450) |
|---|---|
| PCS | LMR-P450, 450 kW, liquid-cooled, Type 4X |
| DC window | 700–1500 V — 314 / 587 / 648 Ah cell systems |
| MV equipment | Integrated MV transformer and MV switchgear, project-specific MV voltage |
| Grid services | Grid-forming, FFR, voltage support, black start |
| Certification path | UL 1741 / IEEE 1547 (PCS), UL 9540 (system) — status on request |
PCS, BMS and battery are engineered as one system and warranted as one system — no finger-pointing between vendors at commissioning.
Factory-tested assemblies arrive with controls pre-integrated, cutting site work to placement, connection and acceptance testing.
U.S.-owned supplier, IP held in the U.S., and a documented FEOC / material-assistance support file for your project's incentive filing.
Compliant products and supply chain
Headquartered in Austin, Texas
Ready for U.S. marketing deployment
Send us a load profile or a single-line diagram — we'll return a configuration and budgetary pricing.
Start the Conversation